Increasing demands for compliance with safety systems and overfill protection have mandated more reliable point level measurement. For more than 80 years, magnetrol level controls and flow controls have been transforming industrial processes. Magnetrol logo the customers first call when performance matters. With the td1 td2, the effect of changing process temperature has been greatly reduced. Our market leadership is sustained by a strong ongoing commitment to advance the stateoftheart in level and flow technologies. One is the reference and the second is heated to a temperature above the process temperature. Product line quick reference magnetrol international. Gostr ta2axxxx4x consult magnetrol for details the txr probe complies with ca nd iel ec tro qu m s of ansiisa 12. Magnetrol offers an extensive range of innovative level, flow and volume controls for process industries.
Ultrasonicnoncontact transmittersforlevel, volume,oropenchannelflow description echotel models 344 and 345 are fullfeatured, ultrasonic noncontact transmitters that provide continuous mea surement for liquid level, volume, or open channel flow applications. T35003nb1a datasheetpdf magnetrol international, inc. Raw data editor o fixed program crash when attempting to copy and paste a record. The td1 is a 24 v dc line powered unit with integral electronics and a builtin dpdt relay. The certification was obtained in december, 1985 and iso 9001 was obtained march 1989 for the first time. Magnetrol has its quality assurance system certified in accordance with bs 5750 part 1 and ns 5801. Magnetrol international uk, burgess hill, west sussex, rh15 9tl. Magnetrol, alldatasheet, datasheet, datasheet search site for electronic components and. The factory default settings are marked on the sticker on the electronics. May 25, 2017 magnetrol, thermatel td2 repairs by dynamics circuit s pte. As the innovator of the first magnetic liquid level switch and pioneer of todays level and flow technology breakthroughs, magnetrol manufactures instrumentation that is more intelligent, more reliable and simpler to install and operate making it far more easy for.
For many applications, the tdr2000 is an economical and superior alternative to capacitance, ultrasonic, and. Td1 td2 bring you the latest in thermal dispersion. The magnetic field viewer offers outstanding performance to inspection of these magnetic media and machines. Magnetrol, thermatel td2 repairs by dynamics circuit s pte. These units have been tested to en 626 and are in compliance with the emc directive 89336eec. These include eclipse guided wave radar transmitters, echotel ultrasonic switches, and thermatel thermal dispersion switches. Continuous diagnostics with fault indication, temperature compensation, narrow hysteresis and fast response time make the td1td2 the latest in thermal dispersion switch technology. Thermatel td1 td2 switches can easily be adjusted to detect flow gases and liquids, level or. Rotatable housing to permit viewing the display from any position. The repair of electronics is our core business, therefore, unlike original equipment manufacturers, we invest all our skill and energy in providing a high quality, cost effective repair solution geared around the needs of our customers.
Valves are made in the usa, manufactured and tested inhouse following quality assurance standards under the. Magnetrol thermatel enhanced model ta2 2x thermal mass flow. The computeraided design cad files and all associated content posted to this website are created, uploaded, managed and owned by third party users. Viewing window filled with dry nitrogen gas to eliminate condensation and allow. T31002n10a datasheet, t31002n10a datasheets, t31002n10a pdf, t31002n10a circuit. Magnetrol liquid level, liquid or airgas flow instrumentation. Using this curve the user can determine the desired set point. Air sonar datasheet search, datasheets, datasheet search site for electronic components and semiconductors, integrated circuits, diodes and other semiconductors. Click on the product category below or use the filters at the left to find the magnetrol products that will meet your flow control challenge. Push buttons for manual testing of alarm and error signals. Ccoe tdxxxxxxcx hazardousapprovalsindia tdxxxxxxgx consult magnetrol for details.
Nov 16, 2015 magnetrol level switch, model a103fmpgtdms1md4dc. Magnetrol tuffy ii liquid level controls with electric switches,alldatasheet, datasheet, datasheet search site for electronic components and semiconductors, integrated circuits. Magnetrol international will repair or replace the control, at no cost to the purchaser, or owner other than. These positions may need to be changed, depending upon uthe application consult the following table. Td2 datasheet, td2 datasheets, td2 pdf, td2 circuit. Td2 can be delivered with a complete calibration curve, allowing the customer to. Consult magnetrol internationals entire thermal dispersion catalogue on. A complete with the td1 td2, the effect of varying process temperature has been greatly reduced. Modulevel pneumatic displacer liquid level control hq co.
A wide variety of magnetrol options are available to you, there are 6 suppliers who sells magnetrol on, mainly located in asia. Products level control flow control volume control software accessories. Model ta2 thermal mass flow transmitter, based on thermal dispersion technology, provides reliable mass measurement for air and gas flow applications the powerful, yet easytouse, electronics are contained in a compact explosionproof enclosure. Alicat scientific mbseries portable laminar mass flow meter. Thermatel td1td2 switches can easily be adjusted to detect. Why choose rockwell automation for your magnetrol 910a1a0001 repair needs. These units are completely sealed and require no periodic maintenance. Today magnetrol products serve industries in over 100 countries. The powerful, yet easy to use, electronics are contained in a compact explosion proof enclosure. Magnetron mi 29g 29 of the old russian radar bar lock the magnetron is a highpowered vacuum tube, that works as selfexcited. Magnetrol, alldatasheet, datasheet, datasheet search site for electronic components and semiconductors, integrated circuits, diodes, triacs, and other semiconductors. Ensure that the sensor is located above the level of thefluid.
Thermatel td2 hygenic level and flow switch, designed for use specifically in the clean or hygienic process industry, the. View online or download magnetrol thermatel td1 installation and operating manual. For more than 75 years, magnatrol has been manufacturing solenoid valves for process control covering a wide range of air and liquid handling applications. The sensor consists of two rtd resistance temperature detector elements. View online or download magnetrol td1 series installation and operating manual. View online or download magnetrol td2 0 series installation and operating manual. Magnetrol offers an extensive range of innovative flow controls for process industries. Find out more about the magnetrol products that will meet your level, flow or interface control challenge.
Thermatel td1td2 thermal dispersion flowlevelinterface switch. Science kit, and others, sell a little box filled with mineral oil with suspended iron filings in it. The td2 is either vdc or v ac line powered, has integral or remote elec. Td1 and td2 thermal dispersion flowlevelinterface switches provide a new level of performance and reliability not found in previous switches. Magnetrol product groups arebased upon these technologies. View and download magnetrol thermatel td1 installation and operating manual online. Top mounted level control switches lead displacers.
The unit utilises magnetrols proven thermal dispersion technology. Thermal dispersion magnetrol international pdf catalogs. The thermatel model td1 td2 switch is utilized in flow, level and interface applications. Thermatel model ta2 thermal mass flow transmitter provides reliable mass measurement for air and gas flow applications. The thermatel td1 and td2 switches utilize the proven thermal dispersion. Continuous diagnostics with fault indication, temperature compensation and fast response time make the td1 td2 the latest in thermal dispersion technology. It is importantthat all instructions are read carefully and followed insequence. Solutions because process environments are so diverse, magnetrol has created numerous technology groups to address the broad range of control challenges. Import pdf mos,mol o the pdf file format has been added to the import options.
T31002n10a datasheet pdf magnetrol international, inc. This box has a hole through the middle to allow the insertion of a cow magnet thats a small cylinder magnet. Follow the procedures in step 5b, steps ae onpage 12. View online or download magnetrol thermatel td2 installation and operating manual. Product line catalogue magnetrol international pdf. View and download magnetrol td1 series installation and operating manual online.
The td1 td2 is popular for pump protection, specifically low flow detection with the unique spherical tip design, to prevent pumps from running dry. Proven process for remanufacturing of ab family of products and repair of nonab products. Datalogger series 4 drive recording device magnetek. Mlis also eliminate vapor or liquid emission problems common with sight and gauge glasses. Magnetrol thermatel td1 installation and operating manual pdf. Thermal dispersion flowlevelinterface switch, td12d00031 datasheet, td12d00031 circuit, td12d00031 data sheet. Thermatel td1td2 switches can easily be adjusted to detect flow gases and liquids, level or. Magnetrol eclipse model 706 guided wave radar level transmitter.
Thermatel ta2 mass flow transmitter magnetrol, lucknow id. Digital es ii modulevel whart communication and analog ez modulevel electronic liquid level transmitters feedwater heaters scrubbers receivers separators interface level knockout drums flash tanks condensate drip pots boilers description the digital es ii and analog ez modulevels are. View online or download magnetrol td2 h0 series installation and operating manual. Magnetrol, thermatel td2 repairs by dynamics circuit s. T10 float level switch online from elcodis, view and download t105104020 pdf datasheet, scrs specifications. The thermatel model td1td2 switch is utilized in flow, level and interface. View and download magnetrol echotel 910 installation and operating manual online. These versatile transmitters utilize the latest in microprocessorbased. Check the nameplate model number model numberapprovals as per inserted separate sheet to be sure it agrees with the packing slip and purchase order. The unit utilises magnetrol s proven thermal dispersion technology.
Td12d00031 datasheetpdf magnetrol international, inc. Through the screen of mv95 magnetic codes on a magnetic card can be observed by simply bringing the viewer s back contact with recorded surface of the card. Digital es ii modulevel whart communication and analog ez. Magnetrol offers a comprehensive line of liquid level as well as liquid or airgas flow instrumentation designed for the sanitary industries. Dec 29, 2015 magnetrol ta2 thermal mass flow meter for flare gas applications 1. Data sheet thermatel td1td2 thermal dispersion switch. Model td2 nc c no nc c no tp2 tp1 l1 l2 model td1 model td2 the td1 td2 switch settings are preset from factory. Td2 pdf, td2 description, td2 datasheets, td2 view. Magnetrol ta2 thermal mass flow meter for flare gas applications. Thermatel model td1 and td2 thermal dispersion flowlevelinterface switches provide a new level of performance and. Td1 and td2 thermal dispersion flowlevelinterface switches provide a new level of performance and reliability not. Magnetrol s series 75 level switches are float operated units suitable for use on clean liquid applications for level alarm. The top countries of suppliers are united states, china, and taiwan, china, from which the percentage of magnetrol supply is 2%, 89%, and 3% respectively. Tuffy ii liquid level controls with electric switches, t35003nb1a datasheet, t35003nb1a circuit, t35003nb1a data sheet.
Echotel models 961 and 962 ultrasonic level switches meet these demands with advanced transducer designs, extensive hazardous location approvals, and a new selftest technology. Displacer type level, interface and density measurement 7xxx 6xxx 5xxx 4xxx 3xxx 2xxx 1xxx installation and operating manual e3modulevel s a f et y i n t e g r i t. Integral or remote electronics rotatable housing to permit viewing the display from. Thermatel td1td2 switches can easily be adjusted to. Modulevel pneumatic displacer liquid level control modulevel pneumatic liquid level controls are displacement actuated level sensors that provide output signals in direct proportion to changes in liquid level. This option imports the pdf file into the active project while retaining all layer information contained in the pdf file. The devices can easily be adjusted to detect flow gases and liquids, level or liquid. Td2 series, td2 0 series, td2 h0 series, td2 d0 series, tdc series, thc series, td2 d0c series. All photos and drawings represent the products at the time of publication 0816. The tdr2000 provides continuous, nonmechanical level measurement, utilizing guided wave radar technology.
It is magnetrol s aim to continue its efforts to strive for quality and performance excellence and to pursue full customer satisfaction. Jacobs and associates is a leading manufacturer and distributor of industrial instrumentation and controls serving all major industrial markets including power generation, chemical, pulp and paper, oil and natural gas production, water and nuclear. The tdr2000 is particularly suited for measuring the level of solids, granules, and powders, as well as a wide range of liquids. Magnetrol thermatelthermaldispersion,alldatasheet, datasheet, datasheet search site for electronic components. The quickstart installation instructions are abrief guide to the sequence of steps for experienced technicians to follow when installing the. Any change in media will cause a low level alarmindication.
890 954 409 1434 1319 46 613 283 409 1619 452 516 123 334 726 1471 1259 1003 916 525 1337 1564 765 1265 1619 1448 257 1309 559 567 830 21 1369 19 125 201 635 820 754